Friday, 9 April 2010

Freehand versus ultrasound-guided core biopsies of the breast: reducing the burden of repeat biopsies in patients presenting to the breast clinic

Freehand versus ultrasound-guided core biopsies of the breast: reducing the burden of repeat biopsies in patients presenting to the breast clinic
S.T. Ward, J.A. Shepherd, H. Khalil
The Breast 2010 19;2:105-108

Link to Journal

In our breast unit a significant proportion of core biopsies are performed freehand sometimes necessitating a repeat biopsy under image guidance. The aims of this study were to establish the proportion of patients undergoing freehand core biopsies who proceeded to a repeat procedure and to determine any factors associated with a missed freehand biopsy. Four hundred and ten core biopsies over 21 months were included in the analysis. Demographic details, position and size of the lump, breast volume and lesion depth were recorded.

Twenty-four percent freehand biopsies were repeated under ultrasound guidance. The histological classification of two-thirds of the repeat biopsies were upgraded, suggesting that the lesion had been previously missed. Multivariate analysis showed that missed freehand biopsies were strongly associated with deep lesions. If all lumps sited at a depth of 6 mm or more were selected for US-guided core biopsy, the workload for the ultrasound department would increase by just less than a half and would have the effect of reducing the freehand biopsy miss rate by almost two-thirds.

Core biopsies should be performed under ultrasound guidance. A freehand technique could be limited to superficial lesions. Depth is more predictive for a missed biopsy than lesion size or breast volume

Tuesday, 16 June 2009

Accuracy of stereotactic vacuum-assisted breast biopsy with a 10-gauge hand-held system

Accuracy of stereotactic vacuum-assisted breast biopsy with a 10-gauge hand-held system
C. Salem, R. Sakr, J. Chopier, C. Marsault, S. Uzan, E. Daraï
The Breast 18, (3), June 2009: 178-182

Link to Journal

The mean number of core specimens obtained per procedure was 9 (range 4–24). Complete radiological excision of the target lesion was achieved in 31.6% (91 of 288) with 91% of these lesions smaller than 10 mm (mean size 7 mm; range 4–20 mm). Under-estimation of ADH and DCIS was 18.2% (2 of 11) and 19.2% (9 of 47), respectively. There was no false negative result within a 3-year follow-up (from 2005 till date). Complications were mild and consisted of immediate bleeding and delayed hematomas