Freehand versus ultrasound-guided core biopsies of the breast: reducing the burden of repeat biopsies in patients presenting to the breast clinic
S.T. Ward, J.A. Shepherd, H. Khalil
The Breast 2010 19;2:105-108
Link to Journal
In our breast unit a significant proportion of core biopsies are performed freehand sometimes necessitating a repeat biopsy under image guidance. The aims of this study were to establish the proportion of patients undergoing freehand core biopsies who proceeded to a repeat procedure and to determine any factors associated with a missed freehand biopsy. Four hundred and ten core biopsies over 21 months were included in the analysis. Demographic details, position and size of the lump, breast volume and lesion depth were recorded.
Twenty-four percent freehand biopsies were repeated under ultrasound guidance. The histological classification of two-thirds of the repeat biopsies were upgraded, suggesting that the lesion had been previously missed. Multivariate analysis showed that missed freehand biopsies were strongly associated with deep lesions. If all lumps sited at a depth of 6 mm or more were selected for US-guided core biopsy, the workload for the ultrasound department would increase by just less than a half and would have the effect of reducing the freehand biopsy miss rate by almost two-thirds.
Core biopsies should be performed under ultrasound guidance. A freehand technique could be limited to superficial lesions. Depth is more predictive for a missed biopsy than lesion size or breast volume
Showing posts with label Ultrasound. Show all posts
Showing posts with label Ultrasound. Show all posts
Friday, 9 April 2010
Sunday, 15 February 2009
Ultrasound guided percutaneous axillary lymph node core biopsy: How often is the sentinel lymph node being biopsied?
Ultrasound guided percutaneous axillary lymph node core biopsy: How often is the sentinel lymph node being biopsied?
P.D. Britton, E. Provenzano, S. Barter, M. Gaskarth, A. Goud, P. Moyle, R. Sinnatamby, M. Wallis, J.R. Benson, P. Forouhi, G.C. Wishart
The Breast 18, 1, 2009, 13-16
Link to Journal
This study aimed to establish the frequency of successful targeting of the SLN by ultrasound guided biopsy. False negative rate for CB of 30%. Reasons for false -ves - failure to sample the sentinel lymph node in 10 (45%) and failure to sample the metastatic disease in the sentinel node in 11 (55%). Better methods of identifying the sentinel lymph node and more adequate sampling are required
P.D. Britton, E. Provenzano, S. Barter, M. Gaskarth, A. Goud, P. Moyle, R. Sinnatamby, M. Wallis, J.R. Benson, P. Forouhi, G.C. Wishart
The Breast 18, 1, 2009, 13-16
Link to Journal
This study aimed to establish the frequency of successful targeting of the SLN by ultrasound guided biopsy. False negative rate for CB of 30%. Reasons for false -ves - failure to sample the sentinel lymph node in 10 (45%) and failure to sample the metastatic disease in the sentinel node in 11 (55%). Better methods of identifying the sentinel lymph node and more adequate sampling are required
Labels:
lymph nodes,
sentinel node biopsy,
SLNB,
Ultrasound
Friday, 19 December 2008
The value of a combination of wire localization and ultrasound-guided vacuum-assisted breast biopsy for clustered microcalcifications
The value of a combination of wire localization and ultrasound-guided vacuum-assisted breast biopsy for clustered microcalcifications
Ki Seok Choo, Hee Suk Kwak, Young Tae Bae, Jee-Yeon Lee, Seung Ju Lee, Hyoung Il Seo, Su Bong Nam
The Breast 17 (2008) 611 - 616
Link to journal
Purpose: to introduce and evaluate the usefulness of the combination of wire localization and ultrasound (US)-guided, vacuum-assisted breast biopsy (VAB) to histologically diagnose mammographically detected clustered microcalcifications in the absence of sonographic and clinically palpable masses. Appears to be an accurate and useful method for diagnosing mammographically detected, clustered microcalcifications
Ki Seok Choo, Hee Suk Kwak, Young Tae Bae, Jee-Yeon Lee, Seung Ju Lee, Hyoung Il Seo, Su Bong Nam
The Breast 17 (2008) 611 - 616
Link to journal
Purpose: to introduce and evaluate the usefulness of the combination of wire localization and ultrasound (US)-guided, vacuum-assisted breast biopsy (VAB) to histologically diagnose mammographically detected clustered microcalcifications in the absence of sonographic and clinically palpable masses. Appears to be an accurate and useful method for diagnosing mammographically detected, clustered microcalcifications
Thursday, 9 October 2008
Evaluation of breast lesions with contrast-enhanced ultrasound using the microvascular imaging technique: Initial observations
Evaluation of breast lesions with contrast-enhanced ultrasound using the microvascular imaging technique: Initial observations
He Liu, Yu-Xin Jiang, Ji-Bin Liu, Qing-Li Zhu, Qiang Sun
The Breast 17 (2008) 532 - 539
Link to Journal
The aim of the paper was to evaluate the usefulness of contrast-enhanced ultrasound using the microvascular imaging technique in the diagnosis of breast lesions. Conventional and contrast-enhanced ultrasound using the microvascular imaging technique were performed after administration of SonoVue. The peripheral enhancement pattern was suggestive of malignancy, with a sensitivity of 39.5%, specificity of 98.3%, PPV of 94.4%, NPV of 69.4%, and accuracy of 73.8%. Homogeneous, regional, and heterogeneous enhancement patterns did not show meaningful diagnostic information
He Liu, Yu-Xin Jiang, Ji-Bin Liu, Qing-Li Zhu, Qiang Sun
The Breast 17 (2008) 532 - 539
Link to Journal
The aim of the paper was to evaluate the usefulness of contrast-enhanced ultrasound using the microvascular imaging technique in the diagnosis of breast lesions. Conventional and contrast-enhanced ultrasound using the microvascular imaging technique were performed after administration of SonoVue. The peripheral enhancement pattern was suggestive of malignancy, with a sensitivity of 39.5%, specificity of 98.3%, PPV of 94.4%, NPV of 69.4%, and accuracy of 73.8%. Homogeneous, regional, and heterogeneous enhancement patterns did not show meaningful diagnostic information
Labels:
breast cancer,
contrast,
sonovue,
Ultrasound
Monday, 2 June 2008
Improving B mode ultrasound evaluation of breast lesions with real-time ultrasound elastography—A clinical approach
S.M. Tan, H.S. Teh, J.F. Kent Mancer and W.T. Poh
The Breast 17, Issue 3, June 2008, Pages 252-257
Link to article
Ultrasound elastography using the extended combined auto-correlation method of tissue elasticity allows for real-time strain image visualisation using a free-hand probe with concurrent conventional B mode imaging. Four hundred and fifteen consecutive women with 550 breast lesions confirmed on B mode ultrasound were assessed with elastography using the elasticity score. There were 119 malignant and 431 benign lesions. The elastography sensitivity was 78.0%, specificity was 98.5% and overall accuracy was 93.8%. The median score for malignancy was 5 and that for benign lesions was 2.
There was good correlation with B mode BIRADS category. 98.6% of lesions with an elasticity score of 2 or below (95%CI=96.8–99.4) were benign. BIRADS 3 lesions with an elasticity score of 2 or below may be re-classified as BIRADS 2 lesions. We found that 15.3% of BIRADS 2 and 3 lesions with an elasticity score of 3 were malignant. Real-time ultrasound elastography is user-friendly with a high accuracy rate, thereby improving B mode ultrasound assessment.
The Breast 17, Issue 3, June 2008, Pages 252-257
Link to article
Ultrasound elastography using the extended combined auto-correlation method of tissue elasticity allows for real-time strain image visualisation using a free-hand probe with concurrent conventional B mode imaging. Four hundred and fifteen consecutive women with 550 breast lesions confirmed on B mode ultrasound were assessed with elastography using the elasticity score. There were 119 malignant and 431 benign lesions. The elastography sensitivity was 78.0%, specificity was 98.5% and overall accuracy was 93.8%. The median score for malignancy was 5 and that for benign lesions was 2.
There was good correlation with B mode BIRADS category. 98.6% of lesions with an elasticity score of 2 or below (95%CI=96.8–99.4) were benign. BIRADS 3 lesions with an elasticity score of 2 or below may be re-classified as BIRADS 2 lesions. We found that 15.3% of BIRADS 2 and 3 lesions with an elasticity score of 3 were malignant. Real-time ultrasound elastography is user-friendly with a high accuracy rate, thereby improving B mode ultrasound assessment.
Labels:
BIRADS,
Elastography,
Real-time,
Ultrasound